Anything you want! Hello


Secular Equilibruim

Determination of radionuclude daughter product abundances can be obtained under the assumption of secular equilibrium. Secular equilibrium is a situation in which the quantity of a radioactive isotope remains constant because its production rate (due, e.g., to decay of a parent isotope) is equal to its decay rate.

Secular equilibrium in radioactive decay

Secular equilibrium can only occur in a radioactive decay chain if the half-life of the daughter radionuclide B is much shorter than the half-life of the parent radionuclide A. In such a situation, the decay rate of A, and hence the production rate of B, is approximately constant, because the half-life of A is very long compared to the timescales being considered. The quantity of radionuclide B builds up until the number of B atoms decaying per unit time becomes equal to the number being produced per unit time; the quantity of radionuclide B then reaches a constant, equilibrium value. The quantity of radionuclide B when secular equilibrium is reached is determined by the quantity of its parent A and the half-lives of the two radionuclide. This can be seen from the time rate of change of the number of atoms of radionuclide B:


where λA and λB are the decay constants of radionuclide A and B, related to their half-lives t1/2 by λ = ln(2) / t1 / 2, and NA and NB are the number of atoms of A and B at a given time. Secular equilibrium occurs when dNB / dt = 0, or Over long enough times, comparable to the half-life of radionuclide A, the secular equilibrium is only approximate; NA decays away according to